| 1 | 	Minimum Horizontal distance of court and yards. (setback) | 	2 mts | 	
	| 2 | 	Minimum number of toilet facilities for Group A Dwellings. | 	1 for each unit | 	
	| 3 | 	Minimum thickness of Foundation Footings on Dwellings units. | 	250mm | 	
	| 4 | 	Minimum Depth below the ground of Foundation Footings on Dwellings units. | 	600mm deep | 	
	| 5 | 	Minimum Floor Live Load at Ground Floor Level. | 	200 kg/sqm. | 	
	| 6 | 	Minimum Floor Live Load at succeeding Upper Floors. | 	150 kg/sqm. | 	
	| 7 | 	Minimum Wind Load Capacity for Roof | 	120 kg/sqm. | 	
	| 8 | 	Minimum width of every Stairs in Group A Dwellings. | 	750mm | 	
	| 9 | 	Minimum Rise and Run for Steps of every Stairs. (conflicting with sec 1207.5.b) | 	200mm & 200mm resp. | 	
	| 10 | 	The required Open Spaces left after deducting the Outermost Face of the Bldg. | 	Yard | 	
	| 11 | 	Minimum Horizontal distance of court and yards. (setback) | 	2 mts | 	
	| 12 | 	Minimum front setback for R1 residentials | 	4.5 m front (2 mts. on sides) | 	
	 | 	Building Height Limits: | 	 | 	
	| 13 | 	Building Height Limits for Residential R-1 and Townhouses R4 | 	3 Storeys or 10mts. | 	
	| 14 | 	Building Height Limits for Condominiums R-5 | 	12-18 Storey/36-54 mts. | 	
	| 15 | 	Building Height Limits for Residential Basic R-2 and R-3 | 	3 Storeys or 10mts. | 	
	| 16 | 	Building Height Limits for Residential Maximum R-2 | 	5 Storey or 15mts. | 	
	| 17 | 	Building Height Limits for Residential Maximum R-3 | 	12 Storeys or 36mts. | 	
	| 18 | 	Building Height Limits for Residential Cultural Buildings, | 	30 mts. | 	
	| 19 | 	Allowed building projections but excluded on BHL computations. | 	Antenna, signages, Towers | 	
	| 20 | 	Maximum building height if ROW is 3 mts. | 	2 Storey or 6 mts. | 	
	| 21 | 	Maximum building height if ROW is 4-5 mts. | 	2.5 Storey or 7.5 mts. | 	
	| 22 | 	Maximum building height if ROW is 6-7mts. | 	3 Storeys or 9mts. | 	
	 | 	Classifications of Occupancy: | 	 | 	
	| 23 | 	GROUP A -- R1 to R5 | 	Residential Dwellings | 	
	| 24 | 	GROUP B -- Multiple Dwellings, Convents/Monasteries, Condominiums, Hotels | 	Residential, Hotels, Apt. | 	
	| 25 | 	GROUP C -- Buildings such as Schools, Colleges and Universities | 	Educ. and Recreation | 	
	| 26 | 	GROUP D -- Buildings like Mental Hospitals, Asylum, Jails and Prisons, Nursing Home and the likes | 	Institutional | 	
	| 27 | 	GROUP E -- Buildings such as Gasoline Stations, Office Bldgs., Retails Stores, Malls | 	Business & Mercantile | 	
	| 28 | 	GROUP F -- Building such as Factories, Ice Plants, Power Plants, Cold Storage, Cremeries, Workshops | 	Industrial | 	
	| 29 | 	GROUP G -- Repair Garages, Aircraft Hangars, other workshops using flammable substances | 	Storage & Hazardous | 	
	| 30 | 	GROUP H -- Assembly other than Group I or 1000 below Occupant Load | 	Assembly - 1000 | 	
	| 31 | 	GROUP I -- Assembly above 1000 Occupant Load | 	Assembly +1000 | 	
	| 32 | 	GROUP J -- Buildings such as Agricultural buildings, private garages, Fence over 1.8mts, tanks, swimming pools) | 	Accessories | 	
	 | 	Type of Construction: (Section 401) | 	 | 	
	| 33 | 	TYPE I - Construction | 	Wood Construction | 	
	| 34 | 	TYPE II - Construction | 	Wood + 1-Hr FR | 	
	| 35 | 	Wood and Masonry with Fire-resistive techniques (of 1 hour) | 	TYPE III | 	
	| 36 | 	Concrete Masonry and Steel and Iron with Fire-resistive techniques (of 1 hour) | 	TYPE IV | 	
	| 37 | 	Concrete Masonry and Steel and Iron with 4-hour Fire-resistive throughout. | 	TYPE V | 	
	 | 	Minimum Off-Street Parking Requirements: (Table VII.4) | 	 | 	
	| 38 | 	Dwelling units R1, R2 and R3 (Single and Multi-Family, Single-Attached or Duplex, Row Houses) with 32-72 sqm. | 	1 per 6 units | 	
	| 39 | 	Dwelling units R1, R2 and R3(Single and Multi-Family, Single-Attached or Duplex, Row Houses) with 50-96 sqm. | 	1 per 4 units | 	
	| 40 | 	Dwelling units R1, R2 and R3(Single and Multi-Family, Single-Attached or Duplex, Row Houses) with 100-120 sqm. | 	1 per unit | 	
	| 41 | 	Dwelling units R4 (Single and Multi-Family, Single-Attached or Duplex, Row Houses) with 50-150 sqm. | 	1 per unit | 	
	| 42 | 	Indigenous Family Dwelling Units | 	1 per 6 units | 	
	| 43 | 	Dwelling units in Condominium Units R5 with 18-22 sqm. GFA | 	1 per 8 units | 	
	| 44 | 	Dwelling units in Condominium Units R5 with 50 sqm. GFA. | 	1 per 6 units | 	
	| 45 | 	Dwelling units in Condominium Units R5 with 100 sqm. GFA | 	1 per 4 units | 	
	| 46 | 	Parking space requirements for Hotels | 	1 per 3 rooms + 2 buses | 	
	| 47 | 	Parking space requirements for Motels | 	1 for every unit | 	
	| 48 | 	Parking space requirements for Bowling Alleys | 	1 per every 4 alleys | 	
	| 49 | 	Parking space requirements for Churches and Places of Worships | 	1 car/50sqm and 1jeep/50sqm | 	
	| 50 | 	Parking space requirements for Public Elementary, Secondary or Vocational School | 	1 per 10 classrooms | 	
	| 51 | 	Parking space requirements for Private Elementary, Secondary or Vocational School | 	1 per 5 classrooms | 	
	| 52 | 	Parking space requirements for Public Colleges and Universities | 	1 per 5 classrooms | 	
	| 53 | 	Parking space requirements for Private Colleges and Universities | 	1 per 3 classrooms | 	
	| 54 | 	Parking space requirements for Private Mental Hospital, Sanitaria and Asylums. | 	1 per 25 beds | 	
	| 55 | 	Parking space requirements for Public Hospitals | 	1 per 25 beds, 2jeeps and | 	
	 | 	 | 	1 articulated truck | 	
	| 56 | 	Parking space requirements for Private Hospitals | 	1 per 12 beds, 2jeeps 7 and | 	
	 | 	 | 	1 articulated truck | 	
	| 57 | 	Parking space requirements for Nursing Homes, Ambulatory, orphanages and the likes. | 	1 per 12 beds | 	
	| 58 | 	Average Car perpendicular and diagonal parking measurement. | 	2.5 x 5 mts. | 	
	| 59 | 	Average Car parallel parking measurement. | 	2.15 x 6 mts. | 	
	| 60 | 	Jeepney parking measurement. | 	3 x 9 mts. | 	
	| 61 | 	Bus/Truck parking measurement. | 	3.6 x 12 mts. | 	
	| 62 | 	Articulated Truck parking measurement. (10 or 12-wheeler trucks) | 	3.6 x 18 mts. | 	
	| 63 | 	Parking space requirements for Terminals, Inter-modals, Depots and the likes. | 	1 per 500 sqm. | 	
	| 64 | 	Parking space requirements for Neighborhood Shopping Center/Supermarkets | 	1 per 100 sqm. | 	
	| 65 | 	Parking space requirements for Restaurants and Fast food, Bars or Beerhouses. | 	1 per 30 sqm. | 	
	| 66 | 	Parking space requirements for Theater Restaurants and Nightclubs. | 	1 per 20 sqm. | 	
	| 67 | 	Parking space requirements for Columbarium | 	1 per Compartment Niche | 	
	| 68 | 	Parking space requirements for Breweries, Mills and other Industrial Buildings | 	1 car per 1000 sqm. | 	
	 | 	 | 	1 bus per 100 workers | 	
	| 69 | 	Parking space requirements for Mercantile Buildings like factories, | 	1 car per 1000 sqm. | 	
	 | 	 | 	1 bus per 100 workers | 	
	| 70 | 	Parking space requirements for public theaters, Cinemas, Assembly Halls, Dance halls, Skating rinks. | 	1 car/jeep per 50 sqm | 	
	| 71 | 	Parking space requirements for Amusement Parks. | 	1 car/jeep per 50 sqm | 	
	| 72 | 	Parking space requirements for Clubhouses, Beach houses and the likes. | 	1 car/jeep per 100 sqm | 	
	| 73 | 	Parking space requirements for Agricultural Buildings if located in urbanized areas. | 	1 per 1000 sqm GFA | 	
	 | 	Types of Lots: (Section VIII) | 	 | 	
	| 74 | 	Lots bounded on all sides with 1 ROW, and 50% Open Space | 	Interior Lots | 	
	| 75 | 	Lots bounded on 3 sides with 1 side facing a street 20% Open Space. | 	Inside Lots | 	
	| 76 | 	Percentage of Open Space for Corner Lots. | 	0.1 | 	
	| 77 | 	Percentage of Open Space for Through Lots. | 	0.05 | 	
	| 78 | 	Percentage of Open Space for Corner-Through Lots. | 	0.05 | 	
	| 79 | 	Percentage of Open Space for End Lots. | 	30-50% | 	
	| 80 | 	The required Open Spaces left after deducting the Outermost Face of the Bldg. | 	Yard | 	
	| 81 | 	Minimum Horizontal distance of court and yards. (setback) | 	2 mts | 	
	| 82 | 	Minimum front setback for R1 residentials | 	4.5 m front (2m sides) | 	
	 | 	General Lighting and Ventilation Requirements (Rule VIII) | 	 | 	
	| 83 | 	Minimum Ceiling Height for Artificially Ventilated rooms on first storey | 	2.70 mts. | 	
	| 84 | 	Minimum Ceiling Height for Artificially Ventilated rooms on succeeding upper storeys. | 	2.40 mts. | 	
	| 85 | 	Minimum Ceiling Height for Naturally Ventilated rooms. | 	2.70 mts. | 	
	| 86 | 	Minimum height of Mezzanine floors | 	1.8 mts. | 	
	| 87 | 	Minimum Area of Rooms for Habitation | 	6 sqm. | 	
	| 88 | 	Minimum Dimension of Rooms for Habitation | 	2 mts. | 	
	| 89 | 	Minimum area for Kitchen. | 	3 sqm | 	
	| 90 | 	Minimum Dimension for Kitchen. | 	1.5 | 	
	| 91 | 	Minimum Area of Toilet and Bath | 	1.2 sqm | 	
	| 92 | 	Minimum Dimension for Toilet and Bath | 	.90 mts | 	
	| 93 | 	Minimum Window openings as related to floor area for Rooms do not provide with artificial Ventilation | 	0.1 | 	
	| 94 | 	Minimum Window openings as related to floor area for Toilet. | 	1/20 or not less than 240 mm ² | 	
	| 95 | 	Minimum clearance of window openings, eaves or canopies to side and rear property lines. | 	750 mm. | 	
	| 96 | 	Minimum width and height for Window openings intended to be used as emergency exits. | 	820 mm X 1000mm resp. | 	
	| 97 | 	Minimum bottom openings for Windows intended to be used as emergency exits. | 	820 mm | 	
	| 98 | 	Minimum area of Vents Shafts | 	1 sqm | 	
	| 99 | 	Minimum dimension of Vents Shafts | 	600 mm | 	
	| 100 | 	Minimum unobstructed area of Air Ducts | 	.30 sqm | 	
	| 101 | 	Minimum center-to-center distance sprinkler heads | 	1.8 mts. | 	
	| 102 | 	Public land and open space which can equally enjoyed by the members of community and strictly not to be | 	Easements | 	
	 | 	used for erection of any building or structures. | 	 | 	
	 | 	General Lighting and Ventilation Requirements (Rule XII) | 	 | 	
	| 103 | 	How many days prior to excavation should the owner inform in writings the adjacent buildings | 	not less than 10 days. | 	
	| 104 | 	What form is the Application of Building Permit. | 	NBC Form B-1 | 	
	| 105 | 	What form is the Application of Fencing Permit. | 	NBC Form B-3 | 	
	| 106 | 	What is NBC Form B-5 | 	Temporary Sidewalk and Occupancy | 	
	| 107 | 	If you need a Scaffolding Permit from the Building Official, what Form are to be filled up? | 	NBC Form B-6 | 	
	| 108 | 	What is NBC Form B-7 | 	Sign Permit | 	
	| 109 | 	What is NBC Form B-8 | 	Demolition Permit | 	
	| 110 | 	What part of ROW was found right after the Property Line? | 	Sidewalk | 	
	| 111 | 	Ideal slope of Play Area? | 	1-2% | 	
	| 112 | 	What slope that doesn’t drain well and needs to be paved? | 	0.01 | 	
	| 113 | 	What NBC Form Deals with Notice of Violation | 	NBC Form B-9 | 	
	| 114 | 	What form is the Certificate of Completion? | 	NBC Form B-10 | 	
	| 115 | 	What form is the Certificate of Occupancy | 	NBC Form B-11 | 	
	| 116 | 	Minimum width of a hallway? | 	1.2 mts. | 	
	| 117 | 	Minimum distance of the Building Main Entrance to the elevator. | 	30 mts. | 	
	| 118 | 	Minimum door width of an elevator? Elevator car minimum dimension? | 	800 mm./ 1.1 x 1.4 mts. | 	
	| 2 | 	Maximum height of a combustible stand. (sec 1207.14.a) | 	2.70 mts. | 	
	| 3 | 	Minimum spacing for seats in a chair type measurement from back-to-back. (sec 1207.14.c.i) | 	850 mm | 	
	| 4 | 	Maximum line of travel to an exit of an aisle without a fire sprinkler system. | 	45.00 mts. | 	
	| 5 | 	Maximum slope of an aisle. (sec 1207.12.e) | 	1:8 | 	
	| 6 | 	In standard seating, the minimum spacing of rows measured from back-to-back. (sec 1207.13.a) | 	840mm | 	
	| 7 | 	Minimum width of any seat. (sec 1207.13.b) | 	450mm | 	
	| 8 | 	Minimum area of a double acting door view panel. (sec 1207.3.a) | 	1,300 sq. cm. | 	
	| 9 | 	Minimum clear width of an exit doorway. (sec 1207.3.c) | 	900 mm | 	
	| 10 | 	Maximum width of an exit door leaf. (sec 1207.3.c) | 	1.20 mts. | 	
	| 11 | 	Minimum width of an exit corridor or exit balcony. (sec 1207.4.a) | 	1.10 mts. | 	
	| 12 | 	Minimum number of exits for floors above the first Storey having an occupant load of more than 10. (sec 1207.2.a) | 	2 exits | 	
	| 13 | 	Number of exits for occupant load of 599-999. (sec 1207.2.a) | 	3 exits | 	
	| 14 | 	Minimum downward projection of a draft curtain (sec 1204.2) | 	0.30 mtr. | 	
	| 15 | 	Maximum floor area for an attic made of combustible materials. (sec 1206.3.a) | 	250.00 sqm | 	
	| 16 | 	Maximum center to center spacing of a draft curtain sprinkler. (sec 1204.2) | 	1.80 mts. | 	
	| 17 | 	Maximum floor area for an attic made of incombustible materials. (1206.3.b) | 	750.00 sqm. | 	
	| 18 | 	Standard gauge for metal hoods in barbeques. (sec 1211.2.b) | 	Ga. 18 | 	
	| 19 | 	Minimum height of a Siamese connection above grade. (sec 1212.2.e) | 	300 mm | 	
	| 20 | 	Standard maximum distance of a Standpipe from an opening in a stairway. (sec 1212.2.c) | 	300 mm | 	
	| 21 | 	Minimum wall thickness of a fireplace. (sec 1211.2.a/e) | 	200 mm | 	
	| 22 | 	Minimum number of exit for a projection room. (sec 1214.3) | 	2 exits (.75 x 2.0 mts) | 	
	| 23 | 	Minimum extended portions of a chimney above the roof. (sec 1211.1.e) | 	600 mm | 	
	| 24 | 	Minimum air space between walls of a masonry chimney above the roof. (sec 1211.1.b.iv) | 	2" / 50 mm | 	
	| 25 | 	Minimum thickness of glass used for floors. | 	12.5 mm | 	
	| 26 | 	Maximum rise of one row of seat to the next for grandstands bleachers (sec 1207.14.c.ii) | 	400 mm / 0.40 mtr. | 	
	| 27 | 	Minimum number of exit for stands within a building serving an occupant load of 300. (sec 1207.2.a) | 	3 exits | 	
	| 28 | 	Minimum height of a guard rail located in front of the grandstand. (sec 1207.14.f.ii) | 	900 mm | 	
	| 29 | 	Minimum width of a run in a grandstand stair. (sec 1207.14.e.i) | 	280 mm | 	
	| 30 | 	Maximum height of a riser in a grandstand stair. (sec 1207.14.e.i) | 	200 mm | 	
	| 31 | 	Minimum spacing for seats with backrests measured from back-to-back (sec 1207.14.c.i) | 	750 mm | 	
	| 32 | 	Minimum spacing for seats without backrests measured from back-to-back. | 	600 mm | 	
	| 33 | 	Minimum width of an exit door in an aisle in Groups H and I. (sec 1207.12.b) | 	1.70 mts. | 	
	| 34 | 	Minimum width of side aisles (sec 1207.12.a) | 	1.10 mts. | 	
	| 35 | 	Minimum width of side aisles serving 1 side only (sec 1207.12.a) | 	800 mm | 	
	| 36 | 	Minimum width of side aisles serving 2 sides (sec 1207.12.a) | 	1.0 mt. | 	
	| 37 | 	Open space requirements for an interior lot. (rule VIII.fig VIII.8) | 	50% of lot area | 	
	| 38 | 	Open space requirements for a corner lot or a through lot. (rule VIII.fig VIII.8) | 	10% of lot area | 	
	| 39 | 	Minimum increase in width of aisles for every linear meter. | 	30 mm | 	
	| 40 | 	Minimum stair width for a Residential Group A Dwellings (sec 708.8) | 	750 mm | 	
	| 41 | 	Standard minimum area of a toilet. (sec 806.1.c) | 	1.20 sqm. | 	
	| 42 | 	Least dimension of a Toilet (sec 806.1.c) | 	900 mm | 	
	| 43 | 	Minimum area of a Kitchen. (sec 806.1.b) | 	3.00 sq.mts. | 	
	| 44 | 	Least dimension of a Kitchen (sec 806.1.b) | 	1.50 mts. | 	
	| 45 | 	Bounded on all sides or around its periphery by building lines. | 	Inner court | 	
	| 46 | 	Minimum area for vent shafts. (sec 809.1) | 	1.00 sqm. | 	
	| 47 | 	Air space requirement for a school room per person. (sec 807.1) | 	3.00 cum. | 	
	| 48 | 	Air space requirement for a Workshop and Factories per person. (sec 807.1) | 	12 cum. | 	
	| 49 | 	Air space requirement for a habitable room per person. (sec 807.1) | 	14.00 cum. | 	
	| 50 | 	Minimum dimension for the opening of an air duct. | 	300 mm | 	
	| 51 | 	Max. projection beyond the property line of a footing along the national road and at least 2.40 mts. in depth. (sec 1002.2) | 	300 mm | 	
	| 52 | 	Max. projection beyond the property line of a footing along the sidewalk and at least .60 mts. in depth. (sec 1002.2) | 	500 mm | 	
	| 53 | 	Minimum clearance of a canopy or a marquee from the sidewalk. (sec 1005.2) | 	3.00 mts. | 	
	| 54 | 	Minimum clearance of an arcade above the sidewalk. | 	3.00 mts. | 	
	| 55 | 	Minimum stair width for occupant load of less than 50. (sec 1207.5.a) | 	0.90 mts. | 	
	| 56 | 	Minimum stair width for occupant load of more than 50. (sec 1207.5.a) | 	1.1 mts. | 	
	| 57 | 	Minimum width of a temporary walkway in front of the building. (sec 1105.1) | 	1.20 mts. | 	
	| 58 | 	Minimum width of a temporary walkway adjacent to the street line of the building. (sec 1105.1) | 	0.60 mts | 	
	| 59 | 	Vacant spaces left between the building and lot lines less than 2.00 mts in width. | 	Setback | 	
	| 60 | 	Minimum horizontal dimensions of a court. (sec 804.1) | 	2.00 mts. | 	
	| 61 | 	Minimum width of a passageway connecting a street and a court. (sec 804.1) | 	1.20 mts. | 	
	| 62 | 	Minimum headroom clearance for a mezzanine. (sec 805.2) | 	1.80 mts. | 	
	| 63 | 	Minimum total area of a window or an opening for a room without artificial ventilation. (sec 808.1) | 	10% of flr. Area | 	
	| 64 | 	Minimum dimension for a vent shaft. (sec 809.1) | 	0.60 mtr. | 	
	| 65 | 	Minimum horizontal clearance of the curb line to the outermost edge of the marquee. (sec 1005.2) | 	300 mm | 	
	| 66 | 	Minimum clearance of the lowest portion of an awning to the ground. (sec 1006.2) | 	2.40 mts. | 	
	| 67 | 	Minimum height of a construction fence. (sec 1006.3) | 	2.40 mts. | 	
	| 68 | 	Minimum height of a protective railing in a construction. (sec 1106.2) | 	1.00 mtr. | 	
	| 69 | 	Maximum height of a handrail above the stair tread. (sec 1207.5.h) | 	900 mm | 	
	| 70 | 	Minimum height of a handrail above the stair tread. (sec 1207.5.h) | 	800 mm | 	
	| 71 | 	Minimum ceiling height for naturally ventilated rooms. (sec 805.1) | 	2.70 mts. | 	
	| 72 | 	Maximum dimension of a stair landing. (sec 1207.5.e) | 	1.20 mts. | 	
	| 73 | 	Maximum slope of an exit court. (sec 1207.10.b) | 	0.0486111111111111 | 	
	| 74 | 	Minimum width of run for circular stair if used as exit. (sec 1207.54.d) | 	250 mm | 	
	| 75 | 	Minimum headroom clearance for any stair. (sec 1207.5.l) | 	2.00 mts. | 	
	| 76 | 	Maximum slope for an exit passageway. (sec 1207.10.b) | 	One is to Eight (1:8) | 	
	| 77 | 	Maximum height of a Siamese connection above the ground. (sec 1212.2.e) | 	1.20 m | 	
	| 78 | 	Maximum distance of any portion of a building from the nozzle of a 23 mts fire hose. (sec 1212.3.c) | 	6.00 mts. | 	
	| 79 | 	Minimum number of exit for any stage. (sec 1213.7) | 	1 per side (or 2 exits) | 	
	| 80 | 	Minimum extension of a proscenium wall above the roof. (sec 1213.4) | 	1.20 mts. | 	
	| 81 | 	Minimum width of a stair in a stage egress. (sec 1213.7) | 	900 mm | 	
	| 82 | 	Minimum width of a stair in a stage egress in each fly gallery. (sec 1213.7) | 	750 mm | 	
	| 83 | 	A store window in which goods are displayed. | 	Show window. | 	
	| 84 | 	Minimum lateral spacing for plastic skylights. (sec 1604.2.c) | 	2.50 mts. | 	
	| 85 | 	Minimum spacing for plastic skylights along the slope of the roof. (sec 1604.2.c) | 	3.00 mts. | 	
	| 86 | 	Minimum distance of a sign from any electrical post or telephone wires. (sec 2004.1.d) | 	1.00 mtr. | 	
	| 87 | 	Maximum width of a business sign. | 	1.20 mts. | 	
	| 89 | 	Minimum size of thread for an entrance or exit step. (sec 811.12.a.v.) | 	300 mm | 	
	| 90 | 	Minimum number of steps for an entrance or exit step. (sec 811.12.a.v.) | 	2 steps | 	
	| 91 | 	Maximum slope for an entrance or exit ramp. (sec 811.12.a.iv) | 	0.0486111111111111 | 	
	| 92 | 	Standard turn circle of a wheelchair. | 	1.50 mts. | 	
	| 93 | 	Standard size of a perpendicular or diagonal parking slot. (sec 707.4.b.) | 	2.50 x 5.00 mts. | 	
	| 94 | 	Standard size of a parallel parking slot. (sec 707.4.b.) | 	2.15 x 5.00 mts. | 	
	| 95 | 	Hotel building parking ratio. (table VII.4.B) | 	1:3 bedrooms | 	
	| 96 | 	Public Hospital building parking ratio. (table VII.4.D) | 	1:25 beds | 	
	| 97 | 	Private Hospital building parking ratio. (table VII.4.D) | 	1:12 beds | 	
	| 98 | 	Maximum distance of a handicapped parking from the facility being served. | 	60.00 mts. | 	
	| 99 | 	Public Colleges and university parking ratio. (table VII.4.C) | 	1:5 classrooms | 	
	| 100 | 	Private Colleges and university parking ratio. (table VII.4.C) | 	1:3 classrooms | 	
	| 101 | 	Theaters, cinemas, auditoria, and stadia parking ratio. (table VII.4.E) | 	1:50 sqm. spectators' area | 	
	| 102 | 	Churches and other places of worship parking ratio. (table VII.4.E) | 	1:50 sqm. congregation area | 	
	| 103 | 	Minimum rise and run of a stair for Group A dwellings (sec 708.8) | 	200 mm | 	
	| 104 | 	Minimum unobstructed headroom clearance from 3rd to succeeding floors. (sec 805.1) | 	2.10 mts. | 	
	| 105 | 	Minimum area of rooms for Human habitation. (sec 806.1.a) | 	6.00 sqm. | 	
	| 106 | 	Least dimension of rooms for human habitation. (sec 806.1.a) | 	2.00 mts. | 	
	| 107 | 	Least dimension of an air duct. (sec 809.3) | 	300 mm | 	
	| 108 | 	Max. encroachment into a public sidewalk of a foundation at least 600 mm below the grade. (sec 1002.3) | 	500 mm | 	
	| 109 | 	Max. encroachment into a public highway of a foundation at least 600 mm below the grade. (sec 1002.3) | 	300 mm | 	
	| 110 | 	Minimum dimension of an exit door. (sec 1207.2.3.c) | 	.90 x 2.00 mts | 	
	| 111 | 	Maximum width reduced by trim, handrails and fully-opened doors to corridors and exit balconies. (sec 1207.4) | 	200 mm | 	
	| 112 | 	Minimum width of stairs serving more than 50 occupants. (sec 1207.5.a) | 	1.10 mts. | 	
	| 113 | 	Minimum width of stairs serving less than 50 occupants. (sec 1207.5.a) | 	.90 mts. | 	
	| 114 | 	Minimum width of stairs serving less than 10 occupants. (sec 1207.5.a) | 	.75 mts. | 	
	| 115 | 	Maximum reduction in width of a stair due to trims and handrails. (sec 1207.5.a) | 	100 mm | 	
	| 116 | 	Minimum run of a winding stair at any point of the steps. (sec 1207.5.) | 	150 mm | 	
	| 117 | 	Allowable maximum vatriations tolerance in the rise and run of every step. (sec 1207.5.b) | 	5 mm | 	
	| 118 | 	Width of stair requiring an intermediate handrail. (sec 1207.5.h) | 	3.00 mts. | 	
	| 119 | 	Minimum width of an aisle serving both sides. (sec 1207.12.a) | 	1.00 mts. | 	
	| 120 | 	Minimum width of an aisle serving one side only. (sec 1207.12.a) | 	1.00 mts. | 	
	| 121 | 	Minimum distance between the back of each seat to the front of the seat behind it. (sec 1207.14.c.i) | 	300 mm | 	
	| 122 | 	Maximum width of seat in a stand. (sec 1207.14.c.iii) | 	480 mm | 	
	| 123 | 	Maximum projection of a penthouse or other projections above the roof. (sec 1210.1) | 	8.40 mts | 	
	| 124 | 	Maximum ratio of a penthouse area to that of the supporting roof. (sec 1210.2) | 	one third (1/3) | 	
	| 125 | 	Minimum thickness of walls of masonry chimney for residentials. (sec 1211.1.b.i) | 	100 mm | 	
	| 126 | 	Minimum thickness of rubble stone masonry chimney for residentials. (sec 1211.1.b.i) | 	300 mm | 	
	| 127 | 	Minimum number of storeys requiring one (1) or more dry standpipes. (sec 1212.2) | 	4 storeys | 	
	| 128 | 	Minimum volume of water a dry standpipe should provide. (sec 1212.2.b) | 	900 liters/minute | 	
	| 129 | 	Diameter of a dry standpipe requiring a two-way Siamese connection. (sec 1212.2.e) | 	4" (100mm) | 	
	| 130 | 	Diameter of a dry standpipe requiring a three-way Siamese connection. (sec 1212.2.e) | 	5" (125mm) | 	
	| 131 | 	Diameter of a dry standpipe requiring a four-way Siamese connection. (sec 1212.2.e) | 	6" (150mm) | 	
	| 132 | 	Minimum height of siamese connection on the street-front of the building. (sec 1212.2.e.) | 	300 mm | 	
	| 133 | 	Maximum height of siamese connection on the street-front of the building. (sec 1212.2.e.) | 	1.2 mts. | 	
	| 134 | 	Minimum volume of water an interior wet standpipe should provide. (sec 1212.3.b) | 	190 liters/minute | 	
	| 135 | 	Minimum volume of water an interior dry standpipe should provide. (sec 1212.3.b) | 	900 liters/minute | 	
	| 136 | 	Minimum diameter of a wet standpipe. (sec 1212.2.b.i) | 	2" (50mm) | 	
	| 137 | 	Standard diameter of a dry standpipe opening. (sec 1212.2.f) | 	2 1/2" (63mm) | 	
	| 138 | 	Standard length of a fire hose (sec 1212.3.c and j) | 	23.00 mts | 	
	| 139 | 	Maximum distance of a hose nozzle to any portion of a building. (sec 1212.3.c) | 	6.00 mts. | 	
	| 140 | 	Standard diameter of a wet standpipe valve. (sec 1212.3.e) | 	38 mm (11/2") | 	
	| 141 | 	Maximum projection into a non-arcaded sidewalk of a signboard. (sec 2004.1.d) | 	1.20 mts | 	
	| 142 | 	Maximum projection into an arcaded sidewalk of a signboard. (sec 2004.1.d.i) | 	.60 mts. | 	
	| 145 | 	Minimum vertical clearance from the bottom of a signage to an arcaded sidewalk. (sec 2004.1.d.ii) | 	5.00 mts. | 	
	| 146 | 	Minimum vertical clearance from the bottom of a signage to non-arcaded sidewalk. (sec 2004.1.d.ii) | 	3.00 mts. | 	
	| 147 | 	Number of days of work abandonment of stoppage for a building permit to expire. (sec 305) | 	120 days (4 mos.) | 	
	| 148 | 	Width of planting strip for sidewalks 2.00 meters in width. (sec 811.D.9) | 	0.80 mtr. | 	
	| 149 | 	Minimum horizontal distance of the curb line to the outermost face of an arcade. (fig. VIII.G.14) | 	500 mm | 	
	| 150 | 	Slope of ramp of road-way to driveway. (sec 8112.12.a.i) | 	1/3 - 1/4 | 	
	 | 	 | 	 | 	
	| 151 | 	Slope of driveway to sidewalk where the height of curb is 200 mm and above. (sec 8112.12.a.i) | 	One is to Eight (1:8) | 	
	| 152 | 	Min. clearance of conductors from any platform or ground or projection from w/c they might be reached. | 	3.00 mts. | 	
	| 153 | 	Minimum clearance of conductors from the highest point of a roof. (sec 1301.5) | 	2.50 mts. | 	
	| 154 | 	Min. vertical cl. of service drop lines above ground at its point of attachment to the building. (sec 1301.5.d) | 	3.00 mts. | 	
	| 155 | 	Min. Vertical cl. of a service drop communication line when crossing a street. (sec 1301.5.d) | 	5.50 mts. | 	
	| 156 | 	Minimum width of an access road to a cul-de-sac. (fig VIII.G.7) | 	3.00 mts. | 	
	 | 	Table XII.1 Gen Requirements for Occupant Load | 	 | 	
	| 157 | 	Unit area per occupant for Dwellings. | 	28.00 sqm. | 	
	| 158 | 	Unit area per occupant for Hotels, Dormitories and Apartments. | 	18.6 sqm. | 	
	| 159 | 	Unit area per occupant for Offices and Garages. | 	9.30 sqm. | 	
	| 160 | 	Unit area per occupant for Classrooms. | 	1.80 sqm. | 	
	| 161 | 	Unit area per occupant for Stores, Retail sales rooms upper floors. | 	5.60 sqm. | 	
	| 162 | 	Unit area per occupant for Stores, Retail sales rooms @ the Basements and Ground Flr. | 	2.80 sqm. | 	
	| 163 | 	Unit area per occupant for Nurseries for children. | 	3.25 sqm. | 	
	| 164 | 	Unit area per occupant for Home for the aged. | 	7.40 sqm. | 	
	| 165 | 	Unit area for Hospitals and Sanitaria. | 	8.40 sqm. | 	
	| 166 | 	Unit area per occupant for aircraft hangars without repairs. | 	46.50 sqm. | 	
	| 167 | 	Unit area per occupant for warehouses and mechanical equipment room. | 	28.00 sqm. | 	
	| 168 | 	Unit area per occupant for Auditoriums, theaters, Dance floor, Churches and the likes. | 	0.65 sqm. | 	
	| 169 | 	Minimum exits for 1st floor and above with occupant load of more than 10. | 	2 exits | 	
	| 170 | 	One or more habitable rooms which are occupied or intended to be occupied by one family with facilities | 	Dwelling unit | 	
	 | 	for cooking , sleeping, living, and eating | 	 | 	
	| 171 | 	That portion of the foundation of a structure which spreads and transmits loads directly to the ground or soil. | 	Footing | 	
	| 172 | 	A continuous horizontal layer of masonry units. | 	Course | 	
	| 173 | 	A room or suite of two or more rooms, designed and intended for , or occupied by one | 	Apartment | 	
	 | 	family for living, sleeping, eating, and cooking purposes. | 	 | 	
	| 174 | 	A stationary open hearth or brazier, either fuel-fired or electric, used for food preparation. | 	Barbecue | 	
	| 175 | 	A portion of the seating space of an assembly room, the lowest part of which is raised 1.20 mts or more above the level of the main | 	Balcony | 	
	| 176 | 	The pipe which connects a flue-burning appliance to a chimney. | 	Chimney connector | 	
	| 177 | 	A hearth & fire chamber or similarly prepared place in w/c a fire may be made & w/c is built in conjunction w/ a chimney. | 	Fireplace | 	
	| 178 | 	A horizontal structural piece which supports the end of the floor beams or joists or walls over opening. | 	Girder | 	
	| 179 | 	Same as heliport except that no refueling, maintenance, repairs, or storage of helicopters is permitted. | 	Helistop | 	
	| 180 | 	A term which may be used synonymously with a partition. | 	Cross wall | 	
	| 181 | 	The vertical supports, such as posts or stanchions, as used in indigenous or traditional types of construction. | 	Suportales | 	
	| 182 | 	Any surface or underground construction covered on top, or any fire-proof construction intended for the storage of valuables. | 	Vault | 	
	| 183 | 	Front yards for commercial buildings abutting a road-right-of-way of 25-29 meters shall have a minimum width…. | 	8.00 mts. | 	
	| 184 | 	Offices shall be provided how many cubic meters of air per person? (sec 807.b) | 	12.00 cum. | 	
	| 185 | 	Multiple living units of up to 6 units built on the same lot shall have an access road directly connecting said | 	 | 	
	 | 	building to a public street w/ a minimum width of how many meters? (table VIII.G.3) | 	3.00 mts. | 	
	| 186 | 	Sidewalks of 2 mts or more in width shall include on its outer side a planting strip of not less than how many mm? | 	800 mm | 	
	| 187 | 	Arcades shall be cantilevered from the building line over the sidewalk and the horizontal clearance between | 	 | 	
	 | 	the curb line and the outermost face of any part of the arcade shall not be less than. | 	500 mm | 	
	| 188 | 	Printing plants shall be classified under what type of occupancy. (sec 701) | 	Business and mercantile | 	
	| 189 | 	Power plants shall be classified under what type of occupancy. (sec 701) | 	Industrial | 	
	| 190 | 	Convents shall be classified under what type of occupancy. (sec 701) | 	Residentials, Hotels and Apt. | 	
	| 191 | 	Repair garages shall be classified under what type of occupancy. (sec 701-Group G-div 4) | 	Storage and Hazardous | 	
	| 192 | 	Reformatories shall be classified under what type of occupancy. | 	Institutional | 	
	| 193 | 	Gasoline stations are under what classification of occupancy | 	Business and mercantile | 	
	| 194 | 	Office Buildings are under what classification of occupancy | 	Business and mercantile | 	
	| 195 | 	Under what classification of occupancy does Mental Hospitals fall? | 	Institutional | 	
	| 196 | 	Under what classification of occupancy does Monasteries fall? | 	Residentials, Hotels and Apt. | 	
	| 197 | 	Under what classification of occupancy does Aircraft Hangars fall? | 	Business and mercantile | 	
	| 198 | 	Under what classification of occupancy does Cold Storage and Creamery fall? | 	Industrial | 	
	| 199 | 	Under what classification of occupancy does Private Garage fall? | 	Accessory | 	
	| 200 | 	Minimum loading slot requirement for Hospitals and hotels. (table VII.4) | 	1 truck loading slot | 	
	 | 	 | 	 | 	
	| 201 | 	Parking requirement for amusement centers. (table VII.4) | 	1:50 sqm of gross floor area | 	
	| 202 | 	Parking requirement for Public Markets (table VII.4) | 	1:150 sqm of flr area for customer, | 	
	 | 	 | 	1:300 sqm for Seller/vendor | 	
	| 203 | 	Parking requirement for neighborhood shopping centers. (table VII.4) | 	1/100 sqm of shopping flr area | 	
	| 204 | 	Parking requirement for multi-family living units of more than 100 sqm of living unit area. (table VII.4) | 	1 per living unit | 	
	| 205 | 	Parking requirement for multi-family living units of up to 50 sqm of living unit area. (table VII.4) | 	1:8 living units | 	
	| 206 | 	Maximum projection of a balcony over a street of over 3 meters but not more than 6 mts. (table X.I) | 	0.60 mtr. | 	
	| 207 | 	Maximum projection of a balcony over a street of 10 mts to less than 11 mts in width. (table X.I) | 	1.00 mtr. | 	
	| 208 | 	Maximum height of 1st the floor for a 2-story wood structure with a height of 7 mts. (table VII.5) | 	4.50 mts. | 	
	| 209 | 	Maximum spacing of posts for 2-storey wooden structure with a height of 8 mts. (table VII.5) | 	4.50 mts. | 	
	| 210 | 	Under what classification of occupancy does fences of over 1.80 meters in height fall? (table VII.1) | 	Accessory | 	
	| 211 | 	Under what classification of occupancy does wood working establishments fall? (table VII.1) | 	Storage and hazardous | 	
	| 212 | 	Under what classification of occupancy does police and fire stations fall? (table VII.1) | 	Institutional (also E-2) | 	
	| 213 | 	Minimum number of exit for an Institutional type of structure. (table XII.1) | 	2 exits | 	
	| 214 | 	Minimum travel distance from exits to any point of the building without a sprinkler system. (sec 1207.2.d) | 	45 mts. | 	
	| 215 | 	Minimum travel distance from exits to any point of the building with a sprinkler system. (sec 1207.2.d) | 	60 mts. | 	
	| 216 | 	A long interior passageway providing access to several rooms. | 	Corridor | 	
	| 217 | 	A raised rim of concrete, stone or metal which forms the edge of a street or sidewalk. | 	Curb | 	
	| 218 | 	The temperature at which a liquid is transformed or converted into vapor. | 	Boiling point | 	
	| 219 | 	Minimum intensity of lights for exits. (sec 1207.11) | 	10.70 lux | 	
	| 220 | 	Minimum live load bearing capacity of a construction canopy. | 	600 kgs./sqm. | 	
	| 221 | 	Minimum lighting for canopies protecting the pedestrian during construction. (sec 1106.4.f) | 	100 Watts for every 6.0 mts. | 	
	| 222 | 	Minimum height of Construction fence. (sec 1106.3) | 	2.40 mts | 	
	| 223 | 	Minimum height of protective railings for temporary walkways. (sec 1106.3) | 	1.0 mt. | 	
	| 224 | 	Minimum thickness of wire-glass for bathtub (sec 1805.1) | 	5.6 mm | 	
	| 225 | 	Minimum thickness of laminated glass for bathtub. (sec 1805.1) | 	6.4 mm | 	
	| 226 | 	Minimum thickness of tempered-glass for bathtub (sec 1805.1) | 	4.8 mm | 	
	| 227 | 	When the distance bet. Inner edge of sidewalk to OFB is less than 1/2 of Building ht. (sec 1106.3.a.b) | 	2.40 ht Fence + Canopy | 	
	| 228 | 	When the distance bet. the outer edge of sidewalk to OFB is less than 1/2 of Building ht. (sec 1106.4.h) | 	2.40 ht Fence, Canopy+net | 	
	| 229 | 	Amount fine for Grave Violation. (sec 211.2.b) | 	10,000 php | 	
	| 230 | 	Violation for non-posting of Occupancy and Building Permit | 	Light Violation | 	
	| 231 | 	Violation for use without appropriate Occupancy Permit. (sec 212.2.) | 	Less Grave | 	
	| 232 | 	Demolition without permit | 	Grave Violation | 	
	 | 	 | 	 | 	
	| 227 | 	Air supply per person per minute for auditoriums. | 	0.30 cum | 	
	| 228 | 	Minimum wind load capacity for roofs for vertical projection. | 	120 kgs./sqm. | 	
	| 229 | 	Minimum thickness of glass for jalousies. | 	5.60 mm | 	
	| 230 | 	Maximum length of glass for jalousies. | 	1.20 mts. | 	
	 | 	 | 	 | 	
	 | 	 | 	 | 	
	 | 	Mins and Max for BP 344 - Disability Laws | 	 | 	
	| 1 | 	Standard Length of a Wheelchair. | 	1.10 - 1.30 mts. | 	
	| 2 | 	Standard Width of a wheelchair. | 	0.60 - 0.75 mts. | 	
	| 3 | 	How many meters above the floor is the comfortable reach of persons confined to a wheelchair. | 	0.70 - 1.20 mts. | 	
	| 4 | 	How many meters is the comfortable clearance for knee and leg space under tables for wheelchair users. | 	0.74 mts. | 	
	| 5 | 	Accessibility, reachability, usability, orientation, workability and efficiency, and ___ are | 	Safety | 	
	| 6 | 	the basic planning requirements of BP344. | 	 | 	
	| 7 | 	Number of wheelchair seating for an assembly seating capacity of 51-300. | 	4 | 	
	| 8 | 	R.A. 7277 | 	Magna Carta for Disabled | 	
	| 9 | 	Turnabout should also be provided at or within how many meters of dead end. | 	3.50 mts. | 	
	| 10 | 	Minimum number of wheelchair seating space for 51-300 seating capacity for auditoriums. | 	4 | 	
	| 11 | 	Minimum Dimensions of an accessible elevator. (bp 344) | 	1.10 X 1.40 mts. | 	
	| 12 | 	Minimum width of a dropped curb. (bp 344) | 	0.90 mtr. | 	
	| 13 | 	Maximum distance of an accessible elevator from the entrance of a building. | 	30.00 mts. | 	
	| 14 | 	Minimum height of signs on walls and doors for the disabled to see comfortably. | 	1.40 mts. | 	
	| 15 | 	Minimum door width for an accessible elevator. | 	0.80 mtr. | 	
	| 16 | 	Minimum dimensions for an accessible water closet stall. | 	1.70 X 1.80 mts. | 	
	| 17 | 	Maximum height of signs on walls and doors for the disabled to see comfortably. | 	1.60 mts. | 	
	| 18 | 	Minimum width of a parking slot for the disabled. | 	3.70 mts. | 	
	| 19 | 	Minimum firebox wall thickness. | 	250 mm | 	
	| 20 | 	Minimum thickness of smoke chamber back walls. | 	150 mm | 	
	| 21 | 	minimum thickness of front and side smoke chamber walls. | 	200 mm | 	
	| 22 | 	Maximum vertical clearance of an arcade above grade. | 	6.00 mts. | 	
	| 23 | 	Minimum vertical cl. of primary lines from the crown of the pavement when crossing the highway. | 	10.00 mts. | 	
	| 24 | 	Minimum vertical cl. of primary lines from top of sidewalk when installed along the side of the highway. | 	7.5 mts. | 	
	| 25 | 	Vertical clearance of secondary lines from sidewalks along or crossing the street. | 	7.5 mts. | 	
	| 26 | 	Maximum height of a dumbwaiter. | 	1.20 mts. | 	
	| 27 | 	Maximum area of a dumbwaiter. | 	3.9 sqm. | 	
	| 28 | 	Maximum capacity of a dumbwaiter. | 	277 kgs. | 	
	| 29 | 	In BP344, the required width of a corridor. | 	1.20 mts. | 	
	| 30 | 	Maximum slope of a drop curb towards the street. | 	0.056 | 	
	| 31 | 	Maximum slope of a drop curb towards adjoining curb. | 	0.05 | 	
	| 32 | 	Maximum spacing for wheelchair turnabouts. | 	12.00 mts. | 	
	| 33 | 	Maximum slope of a ramp. | 	0.05 | 	
	| 34 | 	Maximum distance of handicapped parking from the structure served. | 	60.00 mts. | 	
	| 35 | 	Preferred width of corridor for the disabled. | 	1.50 mts. | 	
	| 36 | 	Maximum height of a water closet from the floor. | 	0.50 mts. | 	
	| 37 | 	Preferred height of switches from the floor. | 	1.10 mts. | 	
	| 38 | 	Minimum height of a switch from the floor. | 	0.90 mts. | 	
	| 39 | 	Maximum height of a switch from the floor. | 	1.20 mts. | 	
	| 40 | 	Least dimension for a parking slot for the disabled. | 	3.70 mts. | 	
	| 41 | 	In BP344, the minimum height of a handrail. | 	0.70 mtr. | 	
	| 42 | 	Maximum length of a ramp for wheelchairs. | 	6.00 mts. | 	
	| 43 | 	Minimum length of a ramp landing for wheelchairs. | 	1.50 mts. | 	
	| 44 | 	In B.P. 344, the maximum slope of a ramp is. | 	0.05 | 	
	| 45 | 	Under B.P. 344, a level area of not less than how many mtr. shall be provided at the top and bottom of any ramp. | 	1.80 mts. | 	
	| 46 | 	What is the common definition of a residential four (R-4) lot or building/ structure? | 	town house | 	
	| 47 | 	What is the common definition of a residential five (R-5) lot or building/ structure? | 	residential condominium | 	
	| 48 | 	What is the common definition of a residential three (R-3) lot or building/ structure? | 	row-house, shop-house or accesso | 	
  
 