1 | Minimum Horizontal distance of court and yards. (setback) | 2 mts |
2 | Minimum number of toilet facilities for Group A Dwellings. | 1 for each unit |
3 | Minimum thickness of Foundation Footings on Dwellings units. | 250mm |
4 | Minimum Depth below the ground of Foundation Footings on Dwellings units. | 600mm deep |
5 | Minimum Floor Live Load at Ground Floor Level. | 200 kg/sqm. |
6 | Minimum Floor Live Load at succeeding Upper Floors. | 150 kg/sqm. |
7 | Minimum Wind Load Capacity for Roof | 120 kg/sqm. |
8 | Minimum width of every Stairs in Group A Dwellings. | 750mm |
9 | Minimum Rise and Run for Steps of every Stairs. (conflicting with sec 1207.5.b) | 200mm & 200mm resp. |
10 | The required Open Spaces left after deducting the Outermost Face of the Bldg. | Yard |
11 | Minimum Horizontal distance of court and yards. (setback) | 2 mts |
12 | Minimum front setback for R1 residentials | 4.5 m front (2 mts. on sides) |
| Building Height Limits: | |
13 | Building Height Limits for Residential R-1 and Townhouses R4 | 3 Storeys or 10mts. |
14 | Building Height Limits for Condominiums R-5 | 12-18 Storey/36-54 mts. |
15 | Building Height Limits for Residential Basic R-2 and R-3 | 3 Storeys or 10mts. |
16 | Building Height Limits for Residential Maximum R-2 | 5 Storey or 15mts. |
17 | Building Height Limits for Residential Maximum R-3 | 12 Storeys or 36mts. |
18 | Building Height Limits for Residential Cultural Buildings, | 30 mts. |
19 | Allowed building projections but excluded on BHL computations. | Antenna, signages, Towers |
20 | Maximum building height if ROW is 3 mts. | 2 Storey or 6 mts. |
21 | Maximum building height if ROW is 4-5 mts. | 2.5 Storey or 7.5 mts. |
22 | Maximum building height if ROW is 6-7mts. | 3 Storeys or 9mts. |
| Classifications of Occupancy: | |
23 | GROUP A -- R1 to R5 | Residential Dwellings |
24 | GROUP B -- Multiple Dwellings, Convents/Monasteries, Condominiums, Hotels | Residential, Hotels, Apt. |
25 | GROUP C -- Buildings such as Schools, Colleges and Universities | Educ. and Recreation |
26 | GROUP D -- Buildings like Mental Hospitals, Asylum, Jails and Prisons, Nursing Home and the likes | Institutional |
27 | GROUP E -- Buildings such as Gasoline Stations, Office Bldgs., Retails Stores, Malls | Business & Mercantile |
28 | GROUP F -- Building such as Factories, Ice Plants, Power Plants, Cold Storage, Cremeries, Workshops | Industrial |
29 | GROUP G -- Repair Garages, Aircraft Hangars, other workshops using flammable substances | Storage & Hazardous |
30 | GROUP H -- Assembly other than Group I or 1000 below Occupant Load | Assembly - 1000 |
31 | GROUP I -- Assembly above 1000 Occupant Load | Assembly +1000 |
32 | GROUP J -- Buildings such as Agricultural buildings, private garages, Fence over 1.8mts, tanks, swimming pools) | Accessories |
| Type of Construction: (Section 401) | |
33 | TYPE I - Construction | Wood Construction |
34 | TYPE II - Construction | Wood + 1-Hr FR |
35 | Wood and Masonry with Fire-resistive techniques (of 1 hour) | TYPE III |
36 | Concrete Masonry and Steel and Iron with Fire-resistive techniques (of 1 hour) | TYPE IV |
37 | Concrete Masonry and Steel and Iron with 4-hour Fire-resistive throughout. | TYPE V |
| Minimum Off-Street Parking Requirements: (Table VII.4) | |
38 | Dwelling units R1, R2 and R3 (Single and Multi-Family, Single-Attached or Duplex, Row Houses) with 32-72 sqm. | 1 per 6 units |
39 | Dwelling units R1, R2 and R3(Single and Multi-Family, Single-Attached or Duplex, Row Houses) with 50-96 sqm. | 1 per 4 units |
40 | Dwelling units R1, R2 and R3(Single and Multi-Family, Single-Attached or Duplex, Row Houses) with 100-120 sqm. | 1 per unit |
41 | Dwelling units R4 (Single and Multi-Family, Single-Attached or Duplex, Row Houses) with 50-150 sqm. | 1 per unit |
42 | Indigenous Family Dwelling Units | 1 per 6 units |
43 | Dwelling units in Condominium Units R5 with 18-22 sqm. GFA | 1 per 8 units |
44 | Dwelling units in Condominium Units R5 with 50 sqm. GFA. | 1 per 6 units |
45 | Dwelling units in Condominium Units R5 with 100 sqm. GFA | 1 per 4 units |
46 | Parking space requirements for Hotels | 1 per 3 rooms + 2 buses |
47 | Parking space requirements for Motels | 1 for every unit |
48 | Parking space requirements for Bowling Alleys | 1 per every 4 alleys |
49 | Parking space requirements for Churches and Places of Worships | 1 car/50sqm and 1jeep/50sqm |
50 | Parking space requirements for Public Elementary, Secondary or Vocational School | 1 per 10 classrooms |
51 | Parking space requirements for Private Elementary, Secondary or Vocational School | 1 per 5 classrooms |
52 | Parking space requirements for Public Colleges and Universities | 1 per 5 classrooms |
53 | Parking space requirements for Private Colleges and Universities | 1 per 3 classrooms |
54 | Parking space requirements for Private Mental Hospital, Sanitaria and Asylums. | 1 per 25 beds |
55 | Parking space requirements for Public Hospitals | 1 per 25 beds, 2jeeps and |
| | 1 articulated truck |
56 | Parking space requirements for Private Hospitals | 1 per 12 beds, 2jeeps 7 and |
| | 1 articulated truck |
57 | Parking space requirements for Nursing Homes, Ambulatory, orphanages and the likes. | 1 per 12 beds |
58 | Average Car perpendicular and diagonal parking measurement. | 2.5 x 5 mts. |
59 | Average Car parallel parking measurement. | 2.15 x 6 mts. |
60 | Jeepney parking measurement. | 3 x 9 mts. |
61 | Bus/Truck parking measurement. | 3.6 x 12 mts. |
62 | Articulated Truck parking measurement. (10 or 12-wheeler trucks) | 3.6 x 18 mts. |
63 | Parking space requirements for Terminals, Inter-modals, Depots and the likes. | 1 per 500 sqm. |
64 | Parking space requirements for Neighborhood Shopping Center/Supermarkets | 1 per 100 sqm. |
65 | Parking space requirements for Restaurants and Fast food, Bars or Beerhouses. | 1 per 30 sqm. |
66 | Parking space requirements for Theater Restaurants and Nightclubs. | 1 per 20 sqm. |
67 | Parking space requirements for Columbarium | 1 per Compartment Niche |
68 | Parking space requirements for Breweries, Mills and other Industrial Buildings | 1 car per 1000 sqm. |
| | 1 bus per 100 workers |
69 | Parking space requirements for Mercantile Buildings like factories, | 1 car per 1000 sqm. |
| | 1 bus per 100 workers |
70 | Parking space requirements for public theaters, Cinemas, Assembly Halls, Dance halls, Skating rinks. | 1 car/jeep per 50 sqm |
71 | Parking space requirements for Amusement Parks. | 1 car/jeep per 50 sqm |
72 | Parking space requirements for Clubhouses, Beach houses and the likes. | 1 car/jeep per 100 sqm |
73 | Parking space requirements for Agricultural Buildings if located in urbanized areas. | 1 per 1000 sqm GFA |
| Types of Lots: (Section VIII) | |
74 | Lots bounded on all sides with 1 ROW, and 50% Open Space | Interior Lots |
75 | Lots bounded on 3 sides with 1 side facing a street 20% Open Space. | Inside Lots |
76 | Percentage of Open Space for Corner Lots. | 0.1 |
77 | Percentage of Open Space for Through Lots. | 0.05 |
78 | Percentage of Open Space for Corner-Through Lots. | 0.05 |
79 | Percentage of Open Space for End Lots. | 30-50% |
80 | The required Open Spaces left after deducting the Outermost Face of the Bldg. | Yard |
81 | Minimum Horizontal distance of court and yards. (setback) | 2 mts |
82 | Minimum front setback for R1 residentials | 4.5 m front (2m sides) |
| General Lighting and Ventilation Requirements (Rule VIII) | |
83 | Minimum Ceiling Height for Artificially Ventilated rooms on first storey | 2.70 mts. |
84 | Minimum Ceiling Height for Artificially Ventilated rooms on succeeding upper storeys. | 2.40 mts. |
85 | Minimum Ceiling Height for Naturally Ventilated rooms. | 2.70 mts. |
86 | Minimum height of Mezzanine floors | 1.8 mts. |
87 | Minimum Area of Rooms for Habitation | 6 sqm. |
88 | Minimum Dimension of Rooms for Habitation | 2 mts. |
89 | Minimum area for Kitchen. | 3 sqm |
90 | Minimum Dimension for Kitchen. | 1.5 |
91 | Minimum Area of Toilet and Bath | 1.2 sqm |
92 | Minimum Dimension for Toilet and Bath | .90 mts |
93 | Minimum Window openings as related to floor area for Rooms do not provide with artificial Ventilation | 0.1 |
94 | Minimum Window openings as related to floor area for Toilet. | 1/20 or not less than 240 mm ² |
95 | Minimum clearance of window openings, eaves or canopies to side and rear property lines. | 750 mm. |
96 | Minimum width and height for Window openings intended to be used as emergency exits. | 820 mm X 1000mm resp. |
97 | Minimum bottom openings for Windows intended to be used as emergency exits. | 820 mm |
98 | Minimum area of Vents Shafts | 1 sqm |
99 | Minimum dimension of Vents Shafts | 600 mm |
100 | Minimum unobstructed area of Air Ducts | .30 sqm |
101 | Minimum center-to-center distance sprinkler heads | 1.8 mts. |
102 | Public land and open space which can equally enjoyed by the members of community and strictly not to be | Easements |
| used for erection of any building or structures. | |
| General Lighting and Ventilation Requirements (Rule XII) | |
103 | How many days prior to excavation should the owner inform in writings the adjacent buildings | not less than 10 days. |
104 | What form is the Application of Building Permit. | NBC Form B-1 |
105 | What form is the Application of Fencing Permit. | NBC Form B-3 |
106 | What is NBC Form B-5 | Temporary Sidewalk and Occupancy |
107 | If you need a Scaffolding Permit from the Building Official, what Form are to be filled up? | NBC Form B-6 |
108 | What is NBC Form B-7 | Sign Permit |
109 | What is NBC Form B-8 | Demolition Permit |
110 | What part of ROW was found right after the Property Line? | Sidewalk |
111 | Ideal slope of Play Area? | 1-2% |
112 | What slope that doesn’t drain well and needs to be paved? | 0.01 |
113 | What NBC Form Deals with Notice of Violation | NBC Form B-9 |
114 | What form is the Certificate of Completion? | NBC Form B-10 |
115 | What form is the Certificate of Occupancy | NBC Form B-11 |
116 | Minimum width of a hallway? | 1.2 mts. |
117 | Minimum distance of the Building Main Entrance to the elevator. | 30 mts. |
118 | Minimum door width of an elevator? Elevator car minimum dimension? | 800 mm./ 1.1 x 1.4 mts. |
2 | Maximum height of a combustible stand. (sec 1207.14.a) | 2.70 mts. |
3 | Minimum spacing for seats in a chair type measurement from back-to-back. (sec 1207.14.c.i) | 850 mm |
4 | Maximum line of travel to an exit of an aisle without a fire sprinkler system. | 45.00 mts. |
5 | Maximum slope of an aisle. (sec 1207.12.e) | 1:8 |
6 | In standard seating, the minimum spacing of rows measured from back-to-back. (sec 1207.13.a) | 840mm |
7 | Minimum width of any seat. (sec 1207.13.b) | 450mm |
8 | Minimum area of a double acting door view panel. (sec 1207.3.a) | 1,300 sq. cm. |
9 | Minimum clear width of an exit doorway. (sec 1207.3.c) | 900 mm |
10 | Maximum width of an exit door leaf. (sec 1207.3.c) | 1.20 mts. |
11 | Minimum width of an exit corridor or exit balcony. (sec 1207.4.a) | 1.10 mts. |
12 | Minimum number of exits for floors above the first Storey having an occupant load of more than 10. (sec 1207.2.a) | 2 exits |
13 | Number of exits for occupant load of 599-999. (sec 1207.2.a) | 3 exits |
14 | Minimum downward projection of a draft curtain (sec 1204.2) | 0.30 mtr. |
15 | Maximum floor area for an attic made of combustible materials. (sec 1206.3.a) | 250.00 sqm |
16 | Maximum center to center spacing of a draft curtain sprinkler. (sec 1204.2) | 1.80 mts. |
17 | Maximum floor area for an attic made of incombustible materials. (1206.3.b) | 750.00 sqm. |
18 | Standard gauge for metal hoods in barbeques. (sec 1211.2.b) | Ga. 18 |
19 | Minimum height of a Siamese connection above grade. (sec 1212.2.e) | 300 mm |
20 | Standard maximum distance of a Standpipe from an opening in a stairway. (sec 1212.2.c) | 300 mm |
21 | Minimum wall thickness of a fireplace. (sec 1211.2.a/e) | 200 mm |
22 | Minimum number of exit for a projection room. (sec 1214.3) | 2 exits (.75 x 2.0 mts) |
23 | Minimum extended portions of a chimney above the roof. (sec 1211.1.e) | 600 mm |
24 | Minimum air space between walls of a masonry chimney above the roof. (sec 1211.1.b.iv) | 2" / 50 mm |
25 | Minimum thickness of glass used for floors. | 12.5 mm |
26 | Maximum rise of one row of seat to the next for grandstands bleachers (sec 1207.14.c.ii) | 400 mm / 0.40 mtr. |
27 | Minimum number of exit for stands within a building serving an occupant load of 300. (sec 1207.2.a) | 3 exits |
28 | Minimum height of a guard rail located in front of the grandstand. (sec 1207.14.f.ii) | 900 mm |
29 | Minimum width of a run in a grandstand stair. (sec 1207.14.e.i) | 280 mm |
30 | Maximum height of a riser in a grandstand stair. (sec 1207.14.e.i) | 200 mm |
31 | Minimum spacing for seats with backrests measured from back-to-back (sec 1207.14.c.i) | 750 mm |
32 | Minimum spacing for seats without backrests measured from back-to-back. | 600 mm |
33 | Minimum width of an exit door in an aisle in Groups H and I. (sec 1207.12.b) | 1.70 mts. |
34 | Minimum width of side aisles (sec 1207.12.a) | 1.10 mts. |
35 | Minimum width of side aisles serving 1 side only (sec 1207.12.a) | 800 mm |
36 | Minimum width of side aisles serving 2 sides (sec 1207.12.a) | 1.0 mt. |
37 | Open space requirements for an interior lot. (rule VIII.fig VIII.8) | 50% of lot area |
38 | Open space requirements for a corner lot or a through lot. (rule VIII.fig VIII.8) | 10% of lot area |
39 | Minimum increase in width of aisles for every linear meter. | 30 mm |
40 | Minimum stair width for a Residential Group A Dwellings (sec 708.8) | 750 mm |
41 | Standard minimum area of a toilet. (sec 806.1.c) | 1.20 sqm. |
42 | Least dimension of a Toilet (sec 806.1.c) | 900 mm |
43 | Minimum area of a Kitchen. (sec 806.1.b) | 3.00 sq.mts. |
44 | Least dimension of a Kitchen (sec 806.1.b) | 1.50 mts. |
45 | Bounded on all sides or around its periphery by building lines. | Inner court |
46 | Minimum area for vent shafts. (sec 809.1) | 1.00 sqm. |
47 | Air space requirement for a school room per person. (sec 807.1) | 3.00 cum. |
48 | Air space requirement for a Workshop and Factories per person. (sec 807.1) | 12 cum. |
49 | Air space requirement for a habitable room per person. (sec 807.1) | 14.00 cum. |
50 | Minimum dimension for the opening of an air duct. | 300 mm |
51 | Max. projection beyond the property line of a footing along the national road and at least 2.40 mts. in depth. (sec 1002.2) | 300 mm |
52 | Max. projection beyond the property line of a footing along the sidewalk and at least .60 mts. in depth. (sec 1002.2) | 500 mm |
53 | Minimum clearance of a canopy or a marquee from the sidewalk. (sec 1005.2) | 3.00 mts. |
54 | Minimum clearance of an arcade above the sidewalk. | 3.00 mts. |
55 | Minimum stair width for occupant load of less than 50. (sec 1207.5.a) | 0.90 mts. |
56 | Minimum stair width for occupant load of more than 50. (sec 1207.5.a) | 1.1 mts. |
57 | Minimum width of a temporary walkway in front of the building. (sec 1105.1) | 1.20 mts. |
58 | Minimum width of a temporary walkway adjacent to the street line of the building. (sec 1105.1) | 0.60 mts |
59 | Vacant spaces left between the building and lot lines less than 2.00 mts in width. | Setback |
60 | Minimum horizontal dimensions of a court. (sec 804.1) | 2.00 mts. |
61 | Minimum width of a passageway connecting a street and a court. (sec 804.1) | 1.20 mts. |
62 | Minimum headroom clearance for a mezzanine. (sec 805.2) | 1.80 mts. |
63 | Minimum total area of a window or an opening for a room without artificial ventilation. (sec 808.1) | 10% of flr. Area |
64 | Minimum dimension for a vent shaft. (sec 809.1) | 0.60 mtr. |
65 | Minimum horizontal clearance of the curb line to the outermost edge of the marquee. (sec 1005.2) | 300 mm |
66 | Minimum clearance of the lowest portion of an awning to the ground. (sec 1006.2) | 2.40 mts. |
67 | Minimum height of a construction fence. (sec 1006.3) | 2.40 mts. |
68 | Minimum height of a protective railing in a construction. (sec 1106.2) | 1.00 mtr. |
69 | Maximum height of a handrail above the stair tread. (sec 1207.5.h) | 900 mm |
70 | Minimum height of a handrail above the stair tread. (sec 1207.5.h) | 800 mm |
71 | Minimum ceiling height for naturally ventilated rooms. (sec 805.1) | 2.70 mts. |
72 | Maximum dimension of a stair landing. (sec 1207.5.e) | 1.20 mts. |
73 | Maximum slope of an exit court. (sec 1207.10.b) | 0.0486111111111111 |
74 | Minimum width of run for circular stair if used as exit. (sec 1207.54.d) | 250 mm |
75 | Minimum headroom clearance for any stair. (sec 1207.5.l) | 2.00 mts. |
76 | Maximum slope for an exit passageway. (sec 1207.10.b) | One is to Eight (1:8) |
77 | Maximum height of a Siamese connection above the ground. (sec 1212.2.e) | 1.20 m |
78 | Maximum distance of any portion of a building from the nozzle of a 23 mts fire hose. (sec 1212.3.c) | 6.00 mts. |
79 | Minimum number of exit for any stage. (sec 1213.7) | 1 per side (or 2 exits) |
80 | Minimum extension of a proscenium wall above the roof. (sec 1213.4) | 1.20 mts. |
81 | Minimum width of a stair in a stage egress. (sec 1213.7) | 900 mm |
82 | Minimum width of a stair in a stage egress in each fly gallery. (sec 1213.7) | 750 mm |
83 | A store window in which goods are displayed. | Show window. |
84 | Minimum lateral spacing for plastic skylights. (sec 1604.2.c) | 2.50 mts. |
85 | Minimum spacing for plastic skylights along the slope of the roof. (sec 1604.2.c) | 3.00 mts. |
86 | Minimum distance of a sign from any electrical post or telephone wires. (sec 2004.1.d) | 1.00 mtr. |
87 | Maximum width of a business sign. | 1.20 mts. |
89 | Minimum size of thread for an entrance or exit step. (sec 811.12.a.v.) | 300 mm |
90 | Minimum number of steps for an entrance or exit step. (sec 811.12.a.v.) | 2 steps |
91 | Maximum slope for an entrance or exit ramp. (sec 811.12.a.iv) | 0.0486111111111111 |
92 | Standard turn circle of a wheelchair. | 1.50 mts. |
93 | Standard size of a perpendicular or diagonal parking slot. (sec 707.4.b.) | 2.50 x 5.00 mts. |
94 | Standard size of a parallel parking slot. (sec 707.4.b.) | 2.15 x 5.00 mts. |
95 | Hotel building parking ratio. (table VII.4.B) | 1:3 bedrooms |
96 | Public Hospital building parking ratio. (table VII.4.D) | 1:25 beds |
97 | Private Hospital building parking ratio. (table VII.4.D) | 1:12 beds |
98 | Maximum distance of a handicapped parking from the facility being served. | 60.00 mts. |
99 | Public Colleges and university parking ratio. (table VII.4.C) | 1:5 classrooms |
100 | Private Colleges and university parking ratio. (table VII.4.C) | 1:3 classrooms |
101 | Theaters, cinemas, auditoria, and stadia parking ratio. (table VII.4.E) | 1:50 sqm. spectators' area |
102 | Churches and other places of worship parking ratio. (table VII.4.E) | 1:50 sqm. congregation area |
103 | Minimum rise and run of a stair for Group A dwellings (sec 708.8) | 200 mm |
104 | Minimum unobstructed headroom clearance from 3rd to succeeding floors. (sec 805.1) | 2.10 mts. |
105 | Minimum area of rooms for Human habitation. (sec 806.1.a) | 6.00 sqm. |
106 | Least dimension of rooms for human habitation. (sec 806.1.a) | 2.00 mts. |
107 | Least dimension of an air duct. (sec 809.3) | 300 mm |
108 | Max. encroachment into a public sidewalk of a foundation at least 600 mm below the grade. (sec 1002.3) | 500 mm |
109 | Max. encroachment into a public highway of a foundation at least 600 mm below the grade. (sec 1002.3) | 300 mm |
110 | Minimum dimension of an exit door. (sec 1207.2.3.c) | .90 x 2.00 mts |
111 | Maximum width reduced by trim, handrails and fully-opened doors to corridors and exit balconies. (sec 1207.4) | 200 mm |
112 | Minimum width of stairs serving more than 50 occupants. (sec 1207.5.a) | 1.10 mts. |
113 | Minimum width of stairs serving less than 50 occupants. (sec 1207.5.a) | .90 mts. |
114 | Minimum width of stairs serving less than 10 occupants. (sec 1207.5.a) | .75 mts. |
115 | Maximum reduction in width of a stair due to trims and handrails. (sec 1207.5.a) | 100 mm |
116 | Minimum run of a winding stair at any point of the steps. (sec 1207.5.) | 150 mm |
117 | Allowable maximum vatriations tolerance in the rise and run of every step. (sec 1207.5.b) | 5 mm |
118 | Width of stair requiring an intermediate handrail. (sec 1207.5.h) | 3.00 mts. |
119 | Minimum width of an aisle serving both sides. (sec 1207.12.a) | 1.00 mts. |
120 | Minimum width of an aisle serving one side only. (sec 1207.12.a) | 1.00 mts. |
121 | Minimum distance between the back of each seat to the front of the seat behind it. (sec 1207.14.c.i) | 300 mm |
122 | Maximum width of seat in a stand. (sec 1207.14.c.iii) | 480 mm |
123 | Maximum projection of a penthouse or other projections above the roof. (sec 1210.1) | 8.40 mts |
124 | Maximum ratio of a penthouse area to that of the supporting roof. (sec 1210.2) | one third (1/3) |
125 | Minimum thickness of walls of masonry chimney for residentials. (sec 1211.1.b.i) | 100 mm |
126 | Minimum thickness of rubble stone masonry chimney for residentials. (sec 1211.1.b.i) | 300 mm |
127 | Minimum number of storeys requiring one (1) or more dry standpipes. (sec 1212.2) | 4 storeys |
128 | Minimum volume of water a dry standpipe should provide. (sec 1212.2.b) | 900 liters/minute |
129 | Diameter of a dry standpipe requiring a two-way Siamese connection. (sec 1212.2.e) | 4" (100mm) |
130 | Diameter of a dry standpipe requiring a three-way Siamese connection. (sec 1212.2.e) | 5" (125mm) |
131 | Diameter of a dry standpipe requiring a four-way Siamese connection. (sec 1212.2.e) | 6" (150mm) |
132 | Minimum height of siamese connection on the street-front of the building. (sec 1212.2.e.) | 300 mm |
133 | Maximum height of siamese connection on the street-front of the building. (sec 1212.2.e.) | 1.2 mts. |
134 | Minimum volume of water an interior wet standpipe should provide. (sec 1212.3.b) | 190 liters/minute |
135 | Minimum volume of water an interior dry standpipe should provide. (sec 1212.3.b) | 900 liters/minute |
136 | Minimum diameter of a wet standpipe. (sec 1212.2.b.i) | 2" (50mm) |
137 | Standard diameter of a dry standpipe opening. (sec 1212.2.f) | 2 1/2" (63mm) |
138 | Standard length of a fire hose (sec 1212.3.c and j) | 23.00 mts |
139 | Maximum distance of a hose nozzle to any portion of a building. (sec 1212.3.c) | 6.00 mts. |
140 | Standard diameter of a wet standpipe valve. (sec 1212.3.e) | 38 mm (11/2") |
141 | Maximum projection into a non-arcaded sidewalk of a signboard. (sec 2004.1.d) | 1.20 mts |
142 | Maximum projection into an arcaded sidewalk of a signboard. (sec 2004.1.d.i) | .60 mts. |
145 | Minimum vertical clearance from the bottom of a signage to an arcaded sidewalk. (sec 2004.1.d.ii) | 5.00 mts. |
146 | Minimum vertical clearance from the bottom of a signage to non-arcaded sidewalk. (sec 2004.1.d.ii) | 3.00 mts. |
147 | Number of days of work abandonment of stoppage for a building permit to expire. (sec 305) | 120 days (4 mos.) |
148 | Width of planting strip for sidewalks 2.00 meters in width. (sec 811.D.9) | 0.80 mtr. |
149 | Minimum horizontal distance of the curb line to the outermost face of an arcade. (fig. VIII.G.14) | 500 mm |
150 | Slope of ramp of road-way to driveway. (sec 8112.12.a.i) | 1/3 - 1/4 |
| | |
151 | Slope of driveway to sidewalk where the height of curb is 200 mm and above. (sec 8112.12.a.i) | One is to Eight (1:8) |
152 | Min. clearance of conductors from any platform or ground or projection from w/c they might be reached. | 3.00 mts. |
153 | Minimum clearance of conductors from the highest point of a roof. (sec 1301.5) | 2.50 mts. |
154 | Min. vertical cl. of service drop lines above ground at its point of attachment to the building. (sec 1301.5.d) | 3.00 mts. |
155 | Min. Vertical cl. of a service drop communication line when crossing a street. (sec 1301.5.d) | 5.50 mts. |
156 | Minimum width of an access road to a cul-de-sac. (fig VIII.G.7) | 3.00 mts. |
| Table XII.1 Gen Requirements for Occupant Load | |
157 | Unit area per occupant for Dwellings. | 28.00 sqm. |
158 | Unit area per occupant for Hotels, Dormitories and Apartments. | 18.6 sqm. |
159 | Unit area per occupant for Offices and Garages. | 9.30 sqm. |
160 | Unit area per occupant for Classrooms. | 1.80 sqm. |
161 | Unit area per occupant for Stores, Retail sales rooms upper floors. | 5.60 sqm. |
162 | Unit area per occupant for Stores, Retail sales rooms @ the Basements and Ground Flr. | 2.80 sqm. |
163 | Unit area per occupant for Nurseries for children. | 3.25 sqm. |
164 | Unit area per occupant for Home for the aged. | 7.40 sqm. |
165 | Unit area for Hospitals and Sanitaria. | 8.40 sqm. |
166 | Unit area per occupant for aircraft hangars without repairs. | 46.50 sqm. |
167 | Unit area per occupant for warehouses and mechanical equipment room. | 28.00 sqm. |
168 | Unit area per occupant for Auditoriums, theaters, Dance floor, Churches and the likes. | 0.65 sqm. |
169 | Minimum exits for 1st floor and above with occupant load of more than 10. | 2 exits |
170 | One or more habitable rooms which are occupied or intended to be occupied by one family with facilities | Dwelling unit |
| for cooking , sleeping, living, and eating | |
171 | That portion of the foundation of a structure which spreads and transmits loads directly to the ground or soil. | Footing |
172 | A continuous horizontal layer of masonry units. | Course |
173 | A room or suite of two or more rooms, designed and intended for , or occupied by one | Apartment |
| family for living, sleeping, eating, and cooking purposes. | |
174 | A stationary open hearth or brazier, either fuel-fired or electric, used for food preparation. | Barbecue |
175 | A portion of the seating space of an assembly room, the lowest part of which is raised 1.20 mts or more above the level of the main | Balcony |
176 | The pipe which connects a flue-burning appliance to a chimney. | Chimney connector |
177 | A hearth & fire chamber or similarly prepared place in w/c a fire may be made & w/c is built in conjunction w/ a chimney. | Fireplace |
178 | A horizontal structural piece which supports the end of the floor beams or joists or walls over opening. | Girder |
179 | Same as heliport except that no refueling, maintenance, repairs, or storage of helicopters is permitted. | Helistop |
180 | A term which may be used synonymously with a partition. | Cross wall |
181 | The vertical supports, such as posts or stanchions, as used in indigenous or traditional types of construction. | Suportales |
182 | Any surface or underground construction covered on top, or any fire-proof construction intended for the storage of valuables. | Vault |
183 | Front yards for commercial buildings abutting a road-right-of-way of 25-29 meters shall have a minimum width…. | 8.00 mts. |
184 | Offices shall be provided how many cubic meters of air per person? (sec 807.b) | 12.00 cum. |
185 | Multiple living units of up to 6 units built on the same lot shall have an access road directly connecting said | |
| building to a public street w/ a minimum width of how many meters? (table VIII.G.3) | 3.00 mts. |
186 | Sidewalks of 2 mts or more in width shall include on its outer side a planting strip of not less than how many mm? | 800 mm |
187 | Arcades shall be cantilevered from the building line over the sidewalk and the horizontal clearance between | |
| the curb line and the outermost face of any part of the arcade shall not be less than. | 500 mm |
188 | Printing plants shall be classified under what type of occupancy. (sec 701) | Business and mercantile |
189 | Power plants shall be classified under what type of occupancy. (sec 701) | Industrial |
190 | Convents shall be classified under what type of occupancy. (sec 701) | Residentials, Hotels and Apt. |
191 | Repair garages shall be classified under what type of occupancy. (sec 701-Group G-div 4) | Storage and Hazardous |
192 | Reformatories shall be classified under what type of occupancy. | Institutional |
193 | Gasoline stations are under what classification of occupancy | Business and mercantile |
194 | Office Buildings are under what classification of occupancy | Business and mercantile |
195 | Under what classification of occupancy does Mental Hospitals fall? | Institutional |
196 | Under what classification of occupancy does Monasteries fall? | Residentials, Hotels and Apt. |
197 | Under what classification of occupancy does Aircraft Hangars fall? | Business and mercantile |
198 | Under what classification of occupancy does Cold Storage and Creamery fall? | Industrial |
199 | Under what classification of occupancy does Private Garage fall? | Accessory |
200 | Minimum loading slot requirement for Hospitals and hotels. (table VII.4) | 1 truck loading slot |
| | |
201 | Parking requirement for amusement centers. (table VII.4) | 1:50 sqm of gross floor area |
202 | Parking requirement for Public Markets (table VII.4) | 1:150 sqm of flr area for customer, |
| | 1:300 sqm for Seller/vendor |
203 | Parking requirement for neighborhood shopping centers. (table VII.4) | 1/100 sqm of shopping flr area |
204 | Parking requirement for multi-family living units of more than 100 sqm of living unit area. (table VII.4) | 1 per living unit |
205 | Parking requirement for multi-family living units of up to 50 sqm of living unit area. (table VII.4) | 1:8 living units |
206 | Maximum projection of a balcony over a street of over 3 meters but not more than 6 mts. (table X.I) | 0.60 mtr. |
207 | Maximum projection of a balcony over a street of 10 mts to less than 11 mts in width. (table X.I) | 1.00 mtr. |
208 | Maximum height of 1st the floor for a 2-story wood structure with a height of 7 mts. (table VII.5) | 4.50 mts. |
209 | Maximum spacing of posts for 2-storey wooden structure with a height of 8 mts. (table VII.5) | 4.50 mts. |
210 | Under what classification of occupancy does fences of over 1.80 meters in height fall? (table VII.1) | Accessory |
211 | Under what classification of occupancy does wood working establishments fall? (table VII.1) | Storage and hazardous |
212 | Under what classification of occupancy does police and fire stations fall? (table VII.1) | Institutional (also E-2) |
213 | Minimum number of exit for an Institutional type of structure. (table XII.1) | 2 exits |
214 | Minimum travel distance from exits to any point of the building without a sprinkler system. (sec 1207.2.d) | 45 mts. |
215 | Minimum travel distance from exits to any point of the building with a sprinkler system. (sec 1207.2.d) | 60 mts. |
216 | A long interior passageway providing access to several rooms. | Corridor |
217 | A raised rim of concrete, stone or metal which forms the edge of a street or sidewalk. | Curb |
218 | The temperature at which a liquid is transformed or converted into vapor. | Boiling point |
219 | Minimum intensity of lights for exits. (sec 1207.11) | 10.70 lux |
220 | Minimum live load bearing capacity of a construction canopy. | 600 kgs./sqm. |
221 | Minimum lighting for canopies protecting the pedestrian during construction. (sec 1106.4.f) | 100 Watts for every 6.0 mts. |
222 | Minimum height of Construction fence. (sec 1106.3) | 2.40 mts |
223 | Minimum height of protective railings for temporary walkways. (sec 1106.3) | 1.0 mt. |
224 | Minimum thickness of wire-glass for bathtub (sec 1805.1) | 5.6 mm |
225 | Minimum thickness of laminated glass for bathtub. (sec 1805.1) | 6.4 mm |
226 | Minimum thickness of tempered-glass for bathtub (sec 1805.1) | 4.8 mm |
227 | When the distance bet. Inner edge of sidewalk to OFB is less than 1/2 of Building ht. (sec 1106.3.a.b) | 2.40 ht Fence + Canopy |
228 | When the distance bet. the outer edge of sidewalk to OFB is less than 1/2 of Building ht. (sec 1106.4.h) | 2.40 ht Fence, Canopy+net |
229 | Amount fine for Grave Violation. (sec 211.2.b) | 10,000 php |
230 | Violation for non-posting of Occupancy and Building Permit | Light Violation |
231 | Violation for use without appropriate Occupancy Permit. (sec 212.2.) | Less Grave |
232 | Demolition without permit | Grave Violation |
| | |
227 | Air supply per person per minute for auditoriums. | 0.30 cum |
228 | Minimum wind load capacity for roofs for vertical projection. | 120 kgs./sqm. |
229 | Minimum thickness of glass for jalousies. | 5.60 mm |
230 | Maximum length of glass for jalousies. | 1.20 mts. |
| | |
| | |
| Mins and Max for BP 344 - Disability Laws | |
1 | Standard Length of a Wheelchair. | 1.10 - 1.30 mts. |
2 | Standard Width of a wheelchair. | 0.60 - 0.75 mts. |
3 | How many meters above the floor is the comfortable reach of persons confined to a wheelchair. | 0.70 - 1.20 mts. |
4 | How many meters is the comfortable clearance for knee and leg space under tables for wheelchair users. | 0.74 mts. |
5 | Accessibility, reachability, usability, orientation, workability and efficiency, and ___ are | Safety |
6 | the basic planning requirements of BP344. | |
7 | Number of wheelchair seating for an assembly seating capacity of 51-300. | 4 |
8 | R.A. 7277 | Magna Carta for Disabled |
9 | Turnabout should also be provided at or within how many meters of dead end. | 3.50 mts. |
10 | Minimum number of wheelchair seating space for 51-300 seating capacity for auditoriums. | 4 |
11 | Minimum Dimensions of an accessible elevator. (bp 344) | 1.10 X 1.40 mts. |
12 | Minimum width of a dropped curb. (bp 344) | 0.90 mtr. |
13 | Maximum distance of an accessible elevator from the entrance of a building. | 30.00 mts. |
14 | Minimum height of signs on walls and doors for the disabled to see comfortably. | 1.40 mts. |
15 | Minimum door width for an accessible elevator. | 0.80 mtr. |
16 | Minimum dimensions for an accessible water closet stall. | 1.70 X 1.80 mts. |
17 | Maximum height of signs on walls and doors for the disabled to see comfortably. | 1.60 mts. |
18 | Minimum width of a parking slot for the disabled. | 3.70 mts. |
19 | Minimum firebox wall thickness. | 250 mm |
20 | Minimum thickness of smoke chamber back walls. | 150 mm |
21 | minimum thickness of front and side smoke chamber walls. | 200 mm |
22 | Maximum vertical clearance of an arcade above grade. | 6.00 mts. |
23 | Minimum vertical cl. of primary lines from the crown of the pavement when crossing the highway. | 10.00 mts. |
24 | Minimum vertical cl. of primary lines from top of sidewalk when installed along the side of the highway. | 7.5 mts. |
25 | Vertical clearance of secondary lines from sidewalks along or crossing the street. | 7.5 mts. |
26 | Maximum height of a dumbwaiter. | 1.20 mts. |
27 | Maximum area of a dumbwaiter. | 3.9 sqm. |
28 | Maximum capacity of a dumbwaiter. | 277 kgs. |
29 | In BP344, the required width of a corridor. | 1.20 mts. |
30 | Maximum slope of a drop curb towards the street. | 0.056 |
31 | Maximum slope of a drop curb towards adjoining curb. | 0.05 |
32 | Maximum spacing for wheelchair turnabouts. | 12.00 mts. |
33 | Maximum slope of a ramp. | 0.05 |
34 | Maximum distance of handicapped parking from the structure served. | 60.00 mts. |
35 | Preferred width of corridor for the disabled. | 1.50 mts. |
36 | Maximum height of a water closet from the floor. | 0.50 mts. |
37 | Preferred height of switches from the floor. | 1.10 mts. |
38 | Minimum height of a switch from the floor. | 0.90 mts. |
39 | Maximum height of a switch from the floor. | 1.20 mts. |
40 | Least dimension for a parking slot for the disabled. | 3.70 mts. |
41 | In BP344, the minimum height of a handrail. | 0.70 mtr. |
42 | Maximum length of a ramp for wheelchairs. | 6.00 mts. |
43 | Minimum length of a ramp landing for wheelchairs. | 1.50 mts. |
44 | In B.P. 344, the maximum slope of a ramp is. | 0.05 |
45 | Under B.P. 344, a level area of not less than how many mtr. shall be provided at the top and bottom of any ramp. | 1.80 mts. |
46 | What is the common definition of a residential four (R-4) lot or building/ structure? | town house |
47 | What is the common definition of a residential five (R-5) lot or building/ structure? | residential condominium |
48 | What is the common definition of a residential three (R-3) lot or building/ structure? | row-house, shop-house or accesso |
0 Comments
If you have any doubts, suggestions , corrections etc. let me know